PMA(丙二醇甲醚醋酸酯) · 英文 MSDS
Safety Data Sheet
SECTION 1: Identification of the substance/mixture and of the company/undertaking
>Product identifier
- Product name: 1-Methoxy-2-propyl acetate
- CBnumber: CB2429933
- CAS: 108-65-6
- EINECS Number: 203-603-9
- Synonyms: PGMEA,MPA
>Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
>Company Identification
- Company: Linyi Tuohui New Materials Co., Ltd.
- Address: Room A6159, 6F, Building 1, Linyi Software Park, No.6 Yihe Road, Zhimadun Subdistrict, Yishui New Area, Linyi City, Shandong Province, China
- Telephone: +86 176 6460 5089 (Manager Niu) / +86 130 4664 1786 (Manager Li)
- Email: nathan@tuohui-chem.com
- WhatsApp: +86 176 6460 5089
- Emergency telephone: +86 176 6460 5089
SECTION 2: Hazards identification
>GHS Label elements, including precautionary statements
- Symbol(GHS)
- Signal wordWarning
Precautionary statements
Hazard statements
SECTION 3: Composition/information on ingredients
>Substance
- Product name: 1-Methoxy-2-propyl acetate
- Synonyms: PGMEA,MPA
- CAS: 108-65-6
- EC number: 203-603-9
- MF: C6H12O3
- MW: 132.16
SECTION 4: First aid measures
>Description of first aid measures
General advice
If inhaled
In case of skin contact
In case of eye contact
If swallowed
>Most important symptoms and effects, both acute and delayed
>Indication of any immediate medical attention and special treatment needed
SECTION 5: Firefighting measures
>Extinguishing media
Suitable extinguishing media
Unsuitable extinguishing media
>Special hazards arising from the substance or mixture
Carbon oxides
>Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
>Further information
Use water spray to cool unopened containers.
>NFPA 704
SECTION 6: Accidental release measures
>Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
For personal protection see section 8.
>Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
>Methods and materials for containment and cleaning up
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
>Reference to other sections
For disposal see section 13.
SECTION 7: Handling and storage
>Precautions for safe handling
Avoid inhalation of vapour or mist.Avoid exposure - obtain special instructions before use. Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.
For precautions see section 2.2.
>Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
>Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
SECTION 8: Exposure controls/personal protection
>control parameter
Hazard composition and occupational exposure limits
>Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment
Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Full contact
Material: butyl-rubber
Minimum layer thickness: 0,3 mm Break through time: > 480 min
Material tested:Butoject (KCL 897 / Aldrich Z677647, Size M)
Splash contact Material: Nitrile rubber
Minimum layer thickness: 0,4 mm Break through time: 79 min
Material tested:Camatril (KCL 730 / Aldrich Z677442, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact
with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Impervious clothing, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
SECTION 9: Physical and chemical properties
>Information on basic physicochemical properties
- Appearancecolourless clear, liquid
- OdourNo data available
- Odour ThresholdNo data available
- pH4 (200g/l, H2O, 20℃)
- Melting point/freezing pointMelting point/range:< -66 °C at 1.013 hPa
- Initial boiling point and boiling range 145 - 146 °C - lit.
- Flash point45,5 °C - closed cup
- Evaporation rateNo data available
- Flammability (solid, gas)No data available
- Upper/lower flammability or explosive limits Upper explosion limit: 13,1 %(V) Lower explosion limit: 1,3 %(V)
- Vapour pressure3,59 hPa at 20 °C - OECD Test Guideline 104
- Vapour densityNo data available
- Relative density0,97 g/cm3 at 25 °C - lit.
- Water solubility198 g/l at 20 °C
- Partition coefficient: n-octanol/waterlog Pow: 1,2 at 20 °C - OECD Test Guideline 117
- Autoignition temperature333 °C at 1.013 hPa
- Decomposition temperatureNo data available
- Viscosity1,13 mm2/s at 25 °C -
- Explosive propertiesNo data available
- Oxidizing propertiesNo data available
>Other safety information
No data available
SECTION 10: Stability and reactivity
>Reactivity
No data available
>Chemical stability
Stable under recommended storage conditions.
>Possibility of hazardous reactions
>Conditions to avoid
Heat, flames and sparks.
>Incompatible materials
Strong oxidizing agents
>Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Carbon oxides Other decomposition products - No data available
In the event of fire: see section 5
SECTION 11: Toxicological information
>Information on toxicological effects
Acute toxicity
LD50 Dermal - Rat - male and female - > 2.000 mg/kg (OECD Test Guideline 402)
Skin corrosion/irritation
Result: No skin irritation (OECD Test Guideline 404)
Serious eye damage/eye irritation
Result: No eye irritation
Respiratory or skin sensitisation
Did not cause sensitisation on laboratory animals. (OECD Test Guideline 406)
Germ cell mutagenicity
S. typhimurium Result: negative
Carcinogenicity
Reproductive toxicity
Specific target organ toxicity - single exposure
Specific target organ toxicity - repeated exposure
Aspiration hazard
Additional Information
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.
SECTION 12: Ecological information
>Toxicity
static test EC50 - Daphnia magna (Water flea) - > 500 mg/l - 48 h
>Persistence and degradability
Biodegradability Biotic/Aerobic - Exposure time 28 d
Result: 83 % - Readily biodegradable. (OECD Test Guideline 301F)
Biochemical Oxygen Demand (BOD)
Chemical Oxygen Demand (COD)
0,36 mg/l
1,74 mg/g
>Bioaccumulative potential
No data available
>Mobility in soil
>Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
>Toxics Screening Level
>Other adverse effects
SECTION 13: Disposal considerations
>Waste treatment methods
> Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.
> Contaminated packaging
Dispose of as unused product.
SECTION 14: Transport information
>UN number
ADR/RID: 3271 IMDG: 3271 IATA: 3271
>UN proper shipping name
ADR/RID: ETHERS, N.O.S. (Propylene glycol monomethyl ether acetate) IMDG: ETHERS, N.O.S. (Propylene glycol monomethyl ether acetate) IATA: Ethers, n.o.s. (Propylene glycol monomethyl ether acetate)
>Transport hazard class(es)
ADR/RID: 3 IMDG: 3 IATA: 3
>Packaging group
ADR/RID: III IMDG: III IATA: III
>Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
>Special precautions for user
No data available
SECTION 15: Regulatory information
>Safety, health and environmental regulations/legislation specific for the substance or mixture
Regulations on the Safety Management of Hazardous Chemicals
Measures for Environmental Management of New Chemical Substances
SECTION 16: Other information
>Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
>References
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
>Other Information
本页为本站内置的 SDS 本地副本,可在线浏览;如需 PDF 文档,请点击右上角“下载 PDF”按钮。
拓辉新材料